4-3. Indoor Unit (RAS-24NKD-E5,RAS-24NKDX5,
RAS-18NKD-E5, RAS-18NKDX5)
No. Parts name Type Specifications
1 Fan motor (for indoor) AFS-220-31A AC 200 − 240V, 31W
2 Thermo sensor (TA-sensor) ——— 10 kΩ at 25°C
3 Micro Power Module (M01) µRM1260V DC 390 V, Secondary DC 12 V
4 Microcontroller TMP87CM40AN
5 Heat exchanger sensor
——— 10 kΩ at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA
7 Diode (DB01) D3SBA60 4 A, 600 V
8 Capacitor (C63) KMH400VSSN47M22S 4.7µF, 400 V
9 Fuse (F01) BET6.3A T6.3 A, 250 V
10 Varistor (R21, R22) 15G561K 560 V
11 Resistor (R319) RF-2TK5R6 5.6Ω , 2 W
12 Louver motor MP35EA12 Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
13 Relay : (RY04) G5NB-1A Coil DC 12V, 16.7mA, Contact AC 250V, 1A
FILE NO. SVM-06005
4-4. Outdoor Unit (RAS-24NA-E, RAS-24N2AX)
No. Parts name Type Specifications
Output (Rated) 2200 W, 2 poles, 1 phase, 220 − 240 V, 50 Hz
1 Compressor PH400X3CS-4KT1 Winding resistance (Ω ) C-R C-S
(at 20 °C)
Output (Rated) 42 W, 4 poles, 1 phase, 220 − 240 V, 50 Hz
Winding resistance (Ω ) Red-Black White-Black
2 Fan motor (for outdoor)
(at 20 °C)
128 126
FG-240-42A
AC 440 V, 50µF
1.13
2.10
3
Running capacitor
451305L
AC 450 V, 3.0µF
(for fan motor)
RS44B506U0218S
4
5 Magnetic contactor
A35
220 − 240 V, 50 Hz
Running capacitor
(for compressor)
– 13 –