– 16 –
FILE NO. SVM-06005
5-2. RAS-24NKD-E5 / RAS-24NA-E, RAS-24NKDX5 / RAS-24N2AX
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.43 8.5 High 27/19 35/24
Cooling High temperature 0.56 12.5 High 32/23 43/26
Low temperature 0.32 2.0 Low 21/15 21/15
Fan speed
(indoor)
50 Hz
Standard
pressure
P
(MPaG)
Evaporator
Indoor unit
Cross flow fan
Condenser
Propeller fan
Outdoor unit
Cooling
O.D.:15.88 mm O.D.:6.35 mm
Cooling
Gas container connection (Reinstall etc.)
Packed valve
(∅6.35)
Packed valve
(∅15.88)
0.39 m
(Connecting pipe)
∅15.88
0.49 m
(Connecting pipe)
∅6.35
T
P
Refrigerant
R22 1.
68
kg
Mark ( ) means check points of Gas Leak
Capillary tube
∅ 2.4x700 s
Surface temp. of heat
exchanger interchanging
pipe
T
(°C)
Dryer
PH400X3CS-4KT1
Compressor