26
FILE NO. SVM-08032
1. Purpose
The Self-Cleaning operation is to minimize the growth of mold,
bacteria etc. by running the fan and drying so as to keep
the inside of the air conditioner clean.
Self-Cleaning operation
When the cooling or dry operation shuts down, the unit
automatically starts the Self-Cleaning operation which is
then performed for the specified period based on duration
of the operation which was performed prior to the shutdown,
after which the Self-Cleaning operation stops.
2. Operation
1) When the stop signal from the remote controller or
timer-off function is received, only the timer indicator
light.
2) The period of the Self-Cleaning operation is determined
by the duration of the operation performed prior to
the reception of the stop code.
3) After the Self-Cleaning operation has been performed
for the specified period, the unit stops operation.
Unit now performing cooling or dry operation
Press STOP button
Only timer indicator lights, and Self Cleaning operation starts
Time set now elapses
Operation stops
During Self-Cleaning operations: The louver opens
slightly. The indoor fan operates continuously at
a speed of SL rpm.
Cooling: Auto (cooling) Dry
Auto (fan only)
Operation time
Up to 10 minutes
No Self-Cleaning operation
performed (0 minutes)
10 minutes
20 mins.
or longer
No Self-Cleaning operation performed
To stop an ongoing Self-Cleaning operation at any time
Press the start/stop button on the remote controller twice during the Self-Cleaning
operation. [After pressing the button for the first time, press it for the
Self-Cleaning operation times
second time without delay (within 10 minutes)].
Self-Cleaning operation time