1. SPECIFICATIONS
MODEL RAS-18SKP-ES RAS-24SKP-ES
RAS-18SA-ES RAS-24SA-ES
ITEM Cooling Cooling
kW
Phase
V
Hz
Power consumption W
Power factor %
Running A
Current Indoor/Outdoor
Starting current A
Moisture removal lit/h
Noise Indoor (H/M+/M/L+/L) dB
Outdoor (220-240V) dB
Refrigerant Name of refrigerant
Rated amount kg
Refrigerant control
Interconnection Gas side size mm
pipe Connection type
Liquid side size mm
Connection type
Maximum length m
(One way)
Maximum height m
difference
INDOOR UNIT
Dimensions Height mm
Width mm
Depth mm
Net weight kg
Evaporator type
Indoor fan type
Airflow volume High fan
m
3
/h
Medium fan
m
3
/h
Low fan
m
3
/h
Fan motor output W
Air filter
OUTDOOR UNIT
Dimensions Height mm
Width mm
Depth mm
Net weight kg
Condenser type
Outdoor fan type
Airflow volume
m
3
/h
Fan motor output W
Compressor Model
Output W
Safety device
Louver type
Usable outdoor temperature range °C
2600
PA200X2CS-4KU1
1500
15 ~ 43
RAS-18SKP-ES RAS-24SKP-ES
1000
880
20*
2
25*
2
810
56 57
1.65
15*
1
98
2450
93
0.3/7.30 0.3/6.90 0.50/14.70 0.50/12.90
240V 220V
5.35 6.80
1∅
220 - 240
50
1680 2410
Capacity
Power source
220V
5.30
240V
6.85
1640
98 97
44
2.7
31
2.0
44/42/39/37/35 45/43/41/39/37
56 57
R410A
1.70
Capillary tube
∅12.7
Flare connection
∅6.35
Flare connection
Fuse , IOL
320
1050
228
13
Finned tube
Cross flow fan
1100
950
850750
30
Honeycomb woven filter with PP frame
RAS-18SA-ES RAS-24SA-ES
Finned tube
715
780
290
5045
Propeller fan
2400 2550 2450
Automatic louver
42
PA270X3CS-4MU2
2000
Note *1 Chargeless pipe
*2 Maximum pipe