No. Parts name Type Specifications
Output (Rated) 1500W, 2poles, 1phase, 220 – 240V, 50Hz
1 Compressor PA225X3F-4L Winding resistance () Red-Black White-Black
(at 20°C) 1.35 2.68
Output (Rated) 42W, 6poles, 1phase, 220 – 240V, 50Hz
2 Fan motor (for outdoor) HF-240-42A Winding resistance () Red-Black White-Black
(at 20°C) 176.2 290.5
3
Running capacitor
SK45FMP02U2 AC 450V, 2µF
(for fan motor)
4
Running capacitor
SK42CMP45U1 AC 420V, 45µF
(for compressor)
5 Relay VC20FA 220 – 240V, 50Hz, 1P1a
4-3. Outdoor Unit (RAS-18UA-ES)
4-4. Outdoor Unit (RAS-24UAH-ES)
No. Parts name Type Specifications
Output (Rated) 2200W, 2poles, 1 phase, 220 – 240V, 50Hz
1 Compressor PA290X3F-4MS Winding resistance () Red-Black White-Black
(at 20°C) 1.07 2.20
Output (Rated) 51W, 6poles, 1phase, 220 – 240V, 50Hz
2 Fan motor (for outdoor) KPG6-71SB5P-T1 Winding resistance () Red-Black White-Black
(at 20°C) 64.4 127.4
3
Running capacitor
SK45FMP3.5U2 AC 450V, 3.5µF
(for fan motor)
4
Running capacitor
SK42CMP45U1 AC 420V, 45µF
(for compressor)
5 Solenoid coil
VHV AC 220 – 240V
(for 4-way valve)
6 Thermo sensor TE / TD 10k at 25°C / 50k at 25°C
7 Magnetic relay CLK-35J 220 – 240V, 50Hz
8 Transformer FT67 220 – 240V
9 Microcomputer TMP47C840N
10 Varistor (R73, 74, 86) 15G471K 470V
11 Fuse (F01) MT3 T5A, 250V