– 4 –
FILE NO. SVM-02008
1-2
RAS-24UFP-E/24UA-E
RAS-24UFHP-E/24UAH-E RAS-24UFPX/24UAX RAS-24UFPX-T/24UAX-T
RAS-24UFP-AR/24UA-AR
Cooling Heating Cooling
Capacity kW 220V 240V 220V 240V 220V 240V 220V
6.10 6.20 6.80 6.90 6.10 6.20 6.10
Phase 1∅
Power source V 220 – 240 220
Hz 50
Power consumption W 2480 2650 2490 2670 2260 2400 2260
Power factor % 97 90 97 89 91 84 91
Running current
Indoor A 0.45 0.45 0.45 0.45 0.45 0.45 0.45
Outdoor A 11.15 11.85 11.20 12.00 10.75 11.40 10.75
Starting current A 60 55
Moisture removal lit/h 2.5 2.7
Noise
Indoor (H/M/L) dB 46/42/37
Outdoor dB 56 57 57 58 56 57 56
Refrigerant
Name of refrigerant R-22
Rated amount Kg 1.63
Refrigerant control Capillary tube
Gas side size mm ∅15.88
Connection type Flare connection
Liquid side size mm ∅6.35
Interconnection Connection type Flare connection
pipe Maximum length m 15*
1
(One way) 25*
2
Maximum height m
10
difference
RAS-24UFP-E
INDOOR UNIT RAS-24UFHP-E RAS-24UFPX RAS-24UFPX-T
RAS-24UFP-AR
Width mm 1093
Dimensions Height mm 633
Depth mm 208
Net weight Kg 23
Evaporator type Finned tube
Indoor fan type Multi blade fan
High fan m
3
/h 900 930 900
Air volume Medium fan m
3
/h 750 760 750
Low fan m
3
/h 650 660 650
Fan motor output W 50
Air filter Washable -filter
RAS-24UA-E
OUTDOOR UNIT RAS-24UAH-E RAS-24UAX RAS-24UAX-T
RAS-24UA-AR
Width mm 880
Dimensions Height mm 690
Depth mm 310
Net weight Kg 66 65
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 3380 3560 3380 3560 3380 3560 3380
Fan motor output W 65
Compressor
Model PH310X3-4MM PH280X3-4MS
Output W 2200 2000
Safety device IOL, Td Sensor IOL
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43 –10 ~ 24 15 ~ 43 (15 ~ 52)*
MODEL
ITEM
* For RAS-24UA-AR model only