5
FILE NO. SVM-04032
1-2
RAS-24UFP-E3/24UA-E3
RAS-24UFHP-E3/24UAH-E3
RAS-24UFPX3/24UAX3
RAS-24UFPX3-T/24UAX3-T
Cooling Heating Cooling
Capacity kW 220V 240V 220V 240V 220V 240V 220V
6.30 6.30 6.80 6.90 6.40 6.45 6.10
Phase 1
Power source V 220 – 240 220
Hz 50
Power consumption W 2480 2650 2490 2670 2260 2400 2260
Power factor % 97 90 97 89 91 84 91
Running current
Indoor A 0.45 0.45 0.45 0.45 0.45 0.45 0.45
Outdoor A 11.15 11.85 11.20 12.00 10.50 10.80 10.50
Starting current A 60 55
Moisture removal lit/h 2.5 2.7
Noise
Indoor (H/M/L) dB 46/42/37
Outdoor dB 56 57 57 58 56 57 56
Refrigerant
Name of refrigerant R-22
Rated amount kg
Refrigerant control Capillary tube
Gas side size mm 15.88
Connection type Flare connection
Liquid side size mm 6.35
Interconnection Connection type Flare connection
pipe Maximum length m 15*
1
(One way) 25*
2
Maximum height m
10
difference
INDOOR UNIT RAS-24UFHP-E3 RAS-24UFPX3-T
RAS-24UFPX3
Width mm 1093
Dimensions Height mm 633
Depth mm 208
Net weight kg 23
Evaporator type Finned tube
Indoor fan type Multi blade fan
High fan m
3
/h 900 930 900
Air volume Medium fan m
3
/h 750 760 750
Low fan m
3
/h 650 660 650
Fan motor output W 50
Air filter Washable -filter
OUTDOOR UNIT RAS-24UAH-E3 RAS-24UAX3-T
RAS-24UAX3
Width mm 880
Dimensions Height mm 690
Depth mm 310
Net weight kg 64 58
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 3380 3560 3380 3560 3380 3560 3380
Fan motor output W 65
Compressor
Model PH310X3-4MM 2JS386D5BB02
Output W 2200 1800
Safety device IOL, Td Sensor IOL
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43 –10 ~ 24 15 ~ 43
MODEL
ITEM
1.63
1.80
RAS-24UFP-E3
RAS-24UA-E3

Table of Contents