– 6 –
FILE NO. SVM-04032
RAS-24UFP-AR3 / 24UA-AR3
Cooling
Capacity kW
6.40
Phase 1∅
Power source V 220 – 240
Hz 50
Power consumption W
Power factor %
Running current
Indoor A
Outdoor A
Starting current A 67
Moisture removal lit/h 2.5
Noise
Indoor (H/M/L) dB 46/42/37
Outdoor dB
Refrigerant
Name of refrigerant R-22
Rated amount kg
Refrigerant control Capillary tube
Gas side size mm ∅15.88
Connection type Flare connection
Liquid side size mm ∅6.35
Interconnection Connection type Flare connection
pipe Maximum length m 15*
1
(One way) 25*
2
Maximum height m
10
difference
INDOOR UNIT
RAS-24UFP-AR3
Width mm 1093
Dimensions Height mm 633
Depth mm 208
Net weight kg 23
Evaporator type Finned tube
Indoor fan type Multi blade fan
High fan m
3
/h 900
Air volume Medium fan m
3
/h 750
Low fan m
3
/h 650
Fan motor output W 50
Air filter Washable -filter
OUTDOOR UNIT
RAS-24UA-AR3
Width mm 880
Dimensions Height mm 690
Depth mm 310
Net weight kg 58
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h
Fan motor output W 65
Compressor
Model
Output W 1800
Safety device
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 52
MODEL
ITEM
1.63
240V
220V
6.45
2260
2400
91 84
0.45
10.9 10.8
56 57
2JS386D5BB02
3380 3560
IOL