– 7 –
FILE NO. SVM-04032
Note : 1
• Capacity is based on the following temperature conditions.
Note : 2
• Charge refrigerant according to the table below.
refrigerant
*2 Need to charge
Over 15m up to 20m (20g/m) Over 15m up to 25m (30g/m)
refrigerant
Temperature
Condition
JIS C9612-1994 *SSA386/1983
Cooling Heating Cooling
Indoor unit inlet air temperature
(DB) 27°C 20°C 29°C
(WB) 19°C 12°C 19°C
Outdoor unit inlet air temperature
(DB) 35°C 7°C 46°C
(WB) 24°C 6°C 24°C
RAS-18UFHP-E3 / RAS-18UAH-E3 RAS-24UFHP-E3 / RAS-24UAH-E3
RAS-18UFP-E3 / RAS-18UA-E3 RAS-24UFP-E3 / RAS-24UA-E3
RAS-18UFPX3 / RAS-18UAX3 RAS-24UFPX3 / RAS-24UAX3
Refrigerant
RAS-18UFP-AR3 / RAS-18UA-AR3 RAS-24UFP-AR3 / RAS-24UA-AR3
RAS-18UFPX3-T2 / RAS-18UAX3-T2 RAS-24UFPX3-T / RAS-24UAX3-T
*1 No need to charge
15m or less 15m or less