Toshiba RAS-18UKPX3 - Refrigeration Cycle for 24 UKP;24 UA Models

Toshiba RAS-18UKPX3
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
FILE NO. SVM-04008
5-3. RAS-24UKP-E3 / RAS-24UA-E3
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.4 11.0 High 27/19 35/24
Cooling High temperature 0.7 12.0 High 32/23 43/26
Low temperature 0.3 1.0 Low 21/15 21/15
Fan speed
(indoor)
50 Hz
Standard
pressure
P
(MPaG)
Evaporator
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
2JS386D5BB02
Accumulator
Cooling
O.D.:15.88 mm O.D.:6.35 mm
Cooling
Gas container connection (Reinstall etc.)
Packed valve
(6.35)
Packed valve
(15.88)
0.39 m
(Connecting pipe)
15.88
0.49 m
(Connecting pipe)
6.35
T
P
Refrigerant
R22 1.80 kg
Mark ( ) means check points of Gas Leak
Capillary tube
2.4x650 s
Surface temp. of heat
exchanger interchanging
pipe
T
(°C)
Dryer