EasyManua.ls Logo

Toshiba RAS-18UKPX3 - Refrigeration Cycle for 18 UKPX3;18 UAX3 Models

Toshiba RAS-18UKPX3
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
FILE NO. SVM-04008
5-6. RAS-18UKPX3 / RAS-18UAX3
Indoor unit
Cross flow fan
Compressor
Condenser
Propeller fan
Outdoor unit
2JS350D5DA02
O.D.:12.7 mm
O.D.:6.35 mm
Packed valve
(12.7)
Packed valve
(6.35)
T
P
Refrigerant
R22 1.05 kg
Evaporator
0.39 m
(Connecting pipe)
12.7
0.49 m
(Connecting pipe)
6.35
Mark ( ) means check points of Gas Leak
Capillary tube
2.0x700 s
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.4 11.0 High 27/19 35/24
Cooling High temperature 0.5 13.0 High 32/23 43/26
Low temperature 0.3 2.0 Low 21/15 21/15
Fan speed
(indoor)
50 Hz
Standard
pressure
P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe
T
(°C)
Dryer

Table of Contents

Related product manuals