EasyManua.ls Logo

Toshiba RAS-18UKX - Page 31

Toshiba RAS-18UKX
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 30 –
FILE NO. SVM-01010
10 mm
10 mm
50 mm
40 mm
1
2
8-4-4. Wiring connection
<How to connect the connecting cable>
Wiring of the connecting cable can be carried out
without removing of the front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to local
cords) into pipe hole on the wall.
4. Take out the connecting cable through the cable slot
on the rear panel so that it is exploded by about 15
cm long in the front side.
5. Insert the connecting cable fully into the terminal
block and secure it by screw tightly.
6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air
inlet grille on the indoor unit.
Cord clamp
Terminal block
Earth line
Connecting
cable
Screw
Terminal
cover
Screw
Air Inlet grille
Front panel
Fig. 8-4-5
about 15 cm
Connecting cable
CAUTION
Be sure to refer to the wiring system diagram
labeled inside the front panel.
Check local electrical cords and also any specific
wiring instructions or limitation.
NOTE:
Use strand wire only.
Wire type : More
than 1.5 mm
2
(H07RN-F or 245
IEC66) or 1.3 mm
2
(AWG-16)
NOTE:
Connect the earth line
to the metallic part
(i mark) located at
the side of 3P terminal.
<How to install the air inlet grille on the indoor unit>
When attaching the air inlet grille, the contrary of
removed operation is performed.
Fig. 8-4-6
<Stripping length of connecting cable>
Earth line
Fig. 8-4-7
Fig. 8-4-8
Fig. 8-4-9

Related product manuals