EasyManua.ls Logo

Toshiba RAS-22N3KV2-A - Hi POWER Mode; FILTER Indicator; Short Timer

Toshiba RAS-22N3KV2-A
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item
Operation flow and applicable data, etc.
Description
41
FILE NO. SVM-13003
19. FILTER When the elapsed time reaches 1000 hours after
Indicator
conditioner operation, the FILTER indicator lights.
After cleaning the filters, turn off the FILTER indicator.
How to Turn Off FILTER Indicator
Press [RESET] button on the indoor unit.
NOTE :
If [RESET] button is pushed while the FILTER indicator
is not lit, the indoor unit will start the automatic
operation.
18. Hi-POWER
([Hi-POWER] button on the remote controller
is pressed)
When [Hi-POWER] button is pressed while the indoor
unit is in Auto, Cooling or Heating operation, Hi-
Mode
POWER mark is indicated on the display of the remote
controller and the unit operates as follows.
1. Automatic operation
The indoor unit operates in according to the
current operation.
2. Cooling operation
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
The preset temperature drops 1ºC
(The value of the preset temperature on the
3. Heating operation
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
The preset temperature increases 2ºC
(The value of the preset temperature on the
4. The Hi-POWER mode can not be set in Dry
operation
The Hi-POWER operation will be cancelled
when press [Hi-POWER] button again.
20. Short Timer In the normal condition, after switching one
circuit breaker, 3-minute delay time for
compressor and 1 hour for plasma air purifier
are set for the maintenance of the unit.
Purpose
To start the unit immediately for the
purpose of testing, trial...etc, short timer
can be used maintenance of the unit.
Short Timer Setting
Q
Push [ ] button to turn the unit OFF.
R
Set the ope
ration mode or plasma air
purifier on the remote controller without
sending the signal to the unit.
S
Use the tip of the pencil to push the
[CHK] button and hold, “00” will show
on display, then push [SET] button to
make "00" disappear.
T
Push
[ ] button to turn the unit ON.
U
When sho
rt timer is activated, all setting
on the remote controller operates
immediately, besides, all indicatiors on
front panel turn ON continuously for
3 seconds.
1
2
SWING
FA N
FIX
QUIET
Hi POWER
ONE-T
OUCH
COMFOR
T
SLEEP

Table of Contents