Fig. 10-2-1
Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind.
Use 8 mm or 10 mm anchor bolts and nuts.
·
·
· If it is necessary to drain the defrost water, attach drain nipple 13 and cap waterproof 14 to
the bottom plate of the outdoor unit before installing it.
10-2-1. Optional installation parts
10-2. Installation
<Fixing bolt arrangement of outdoor unit>
Part
code
Parts name Q’ty
A
One
each
B
Pipe insulating material
(polyethylene foam, 6 mm thick)
1
C
Putty, PVC tapes
One
each
Refrigerant piping
Liquid side : Ø6.35 mm
Gas side : Ø12.70 mm
RAS-18, 22PAVSG-E RAS-24PAVSG-E
125 mm108 mm
28 mm
320 mm
600 mm
90 mm
Drain outlet
86 mm
102 mm
Ø25 mm
Air outlet
Air inlet
125 mm
108 mm
29 mm
330 mm
600 mm
99 mm
106 mm
121 mm
Ø25 mm
Air outlet
Air inlet
Drain outlet
FILE NO. SVM-17001