– 4 –
FILE NO. SVM-06021
Note : 1
Capacity is based on the following temperature conditions.
Note : 2
Charge refrigerant according to the table below.
Refrigerant
RAS-18GFHP-ES2 / RAS-18GAH-ES2 RAS-24GFHP-ES2 / RAS-24GAH-ES2
RAS-18GFP-ES2 / RAS-18GA-ES2 RAS-24GFP-ES2 / RAS-24GA-ES2
*1 No need to charge
15m or less 15m or less
refrigerant
*2 Need to charge
Over 15m up to 20m (20g/m) Over 15m up to 25m (30g/m)
refrigerant
Temperature
Condition
JIS B615-1
Cooling Heating
Indoor unit inlet air temperature
(DB) 27°C 20°C
(WB) 19°C 15°C
Outdoor unit inlet air temperature
(DB) 35°C 7°C
(WB) 24°C 6°C