EasyManua.ls Logo

Toshiba RAS-24GKHP-ES2 - 4 Specification of Electrical Parts; Indoor Unit (RAS-24 GKHP-ES2, RAS-18 GKHP-ES2); Outdoor Unit (RAS-24 GAH-ES2)

Toshiba RAS-24GKHP-ES2
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FILE NO. SVM-06020
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-24GKHP-ES2, RAS-18GKHP-ES2)
4-2. Outdoor Unit (RAS-24GAH-ES2)
No. Parts name Type Specifications
Output (Rated) 2200W, 2poles, 1 phase, 220 240V, 50Hz
1 Compressor PA290X3CS-4MU1 Winding resistance () Red-Black White-Black
(at 20°C) 1.13 2.10
Output (Rated) 42W, 4poles, 1 phase, 220 – 240V, 50Hz
2 Fan motor (for outdoor) FG-240-42A-1 Winding resistance () Red-Black White-Black
(at 20°C) 128 126
3
Running capacitor
451305L AC 450V, 3.0µF
(for fan motor)
4
Running capacitor
RS44B506U0218S AC 440V, 50µF
(for compressor)
5
Solenoid coil
VHV (STF) AC 220 ~ 240V
(for 4-way valve)
6 Thermo sensor TE / TD 10k at 25°C / 50k at 25°C
7 Magnetic contactor CLK-35J 220 ~ 240V, 50Hz
8 Transformer TT-05 220 ~ 240V
9 Microcontroller TMP47C840N
10 Varistor (R73, R74) 15G471K 470V
11 Fuse (F01) TSCR T6.3A, 250V
No. Parts name Type Specifications
1 Fan motor (for indoor) AFS-220-31-4A AC 200 240V, 31W
2 Thermo sensor (TA-sensor) ——— 10 k at 25°C
3 Micro Power Module (M01) µRM1260V DC 390 V, Secondary DC 12 V
4 Microcontroller TMP87CM40AN
5 Heat exchanger sensor
——— 10 k at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA
7 Diode (DB01) D3SBA60 4 A, 600 V
8 Capacitor (C63) EKMH401VSN470MP20S 4.7µF, 400 V
9 Fuse (F01) BET6.3A T6.3 A, 250 V
10 Varistor (R21, R22) TND15G561K 560 V
11 Resistor (R319) RF-2TK5R6 5.6 , 2 W
12 Louver motor 35BYJ46 Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
- 12 -

Table of Contents