EasyManua.ls Logo

Toshiba RAS-24GKP-ES2 - Refrigeration Cycle: RAS-18 GKP;GA-ES2

Toshiba RAS-24GKP-ES2
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FILE NO. SVM-06020
5-4. RAS-18GKP-ES2 / RAS-18GA-ES2
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard 1.1 10.0 High 27/19 35/24
Cooling Overload 1.2 13.0 High 32/23 43/26
Low temperature 0.6 2.0 Low 21/15 21/15
Fan speed
(indoor)
50Hz
Standard
pressure
P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe
T1
(°C)
Indoor unit
Cross flow fan
Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
PA225X2CS-4KU1
Cooling
Mark(
)means check points of Gas Leak.
O.D.:12.7mm
O.D.:6.35mm
Cooling
Packed valve
(
12.7)
Packed valve
(
6.35)
0.39m
(Connecting pipe)
12.7
0.49m
(Connecting pipe)
6.35
T1
P
Refrigerant
R410A 1.
26 kg
Evaporator
Capillary tube
1.7x400
s
- 18 -

Table of Contents