6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1
2
3
4
Room temp. sensor (TA-sensor)
Heat exchanger temp. sensor (TC-sensor)
Louver motor
ICF-340-30-2Β
( — )
( — )
MP24Z3N
DC340V, 30W
10k at 25°C
10k at 25°C
FILE NO. SVM-13004
Fan motor (for indoor)
Parts name
Type
Specifications
5
Heat exchanger temp. sensor (TCJ-sensor) ( — )
4 phase, 16 poles, DC12V
10k at 25°C
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Parts name
Compressor
Outdoor fan motor
Reactor
4-way valve coil
PMV coil
P.C. board
Fuse (Mounted on P.C. board)
Fuse (Mounted on P.C. board)
Fuse (Mounted on P.C. board)
Outdoor temp. sensor (TO sensor)
Heat exchanger sensor (Te sensor)
Discharge temp. sensor (Td sensor)
Heat exchanger Temp sensor (Ts sensor)
Compressor thermo. (Protection)
Type
DA220A2F-22L
ICF-280-A60-1
CH-56
VHV-H01AP1874A1
CAM-MD12TCTH-6
MCC-1571
CS-12AL
Specifications
Output 60 W
5.8 mH, 18.5 A
AC200 ~ 240 V
DC12 V
AC220 ~ 240 V
AC250 V, 25 A
AC250 V, 10 A
AC250 V, 3.15 A
10 k at 25°C
10 k at 25°C
50 k at 25°C
10 k at 25°C
OFF: 125 ± 4°C, ON: 90 ± 5°C