4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-24SKP-ES2)
– 10 –
FILE NO. SVM-10049
1 Fan motor (for indoor) MF-340-30-1RT DC 340V, 30W
2 Thermo sensor (TA-sensor) ——— 10 kΩ at 25°C
3 Switching Transformer (T01) SWT-77 DC7V, 12 V
4 Microcontroller TMP87CM40ANG-6P68
5 Heat exchanger sensor
——— 10 kΩ at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-R06270 27mH, 600mA
7 Diode (DB01) D3SBA60 4 A, 600 V
8 Capacitor (C03) EKMH451VSN121MQ35S 120 µF, 450 V
9 Fuse (F01) BET6.3A 6.3 A, 250 V
10 Varistor (R09, R10) SR561K14DO 560 V
11 Resistor (R01) RF-5TK1R8
No.
1.8Ω ,
P
5W
ar
1
ts name
2
T
Lou
ype
v
Specifications
er motor MP24Z3T
Output (Rated) 2 W, 16 poles, 4 phase,
DC 12 V
13
G5NB-1A-CA
Relay : (RY03)
Coil DC 12V, 16.7mA, Contact AC 250V, 3A
4-2. Outdoor Unit (RAS-24SA-ES2)
No. Parts name Type Specifications
Output (Rated) 2000W, 2poles, 1 phase, 220-240V 50Hz
1 Compressor PA271X3CS-4MU2 Winding resistance (Ω ) Red-Black White-Black
(at 20°C) 1.27 2.10
Output (Rated) 42W, 4poles, 1 phase, 220 − 240V, 50Hz
2 Fan motor (for outdoor) WLF-240-85A Winding resistance (Ω) Red-Black White-Black
(at 20° C) 70.5 120.1
3
Running capacitor
DS451355NPQB AC 450V, 3.0µ F
(for fan motor)
4
Running capacitor
B
32332I5606J063 A
C 450V, 60µ F
(for compressor)
5
Magnetic contactor
A35P 220-240V, 50Hz