EasyManua.ls Logo

Toshiba RAS-24SKP-ES2 - Specification of Electrical Parts; 4-1. Indoor Unit (RAS-24 SKP-ES2); 4-2. Outdoor Unit (RAS-24 SA-ES2)

Toshiba RAS-24SKP-ES2
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-24SKP-ES2)
10
FILE NO. SVM-10049
1 Fan motor (for indoor) MF-340-30-1RT DC 340V, 30W
2 Thermo sensor (TA-sensor) ——— 10 k at 25°C
3 Switching Transformer (T01) SWT-77 DC7V, 12 V
4 Microcontroller TMP87CM40ANG-6P68
5 Heat exchanger sensor
——— 10 k at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-R06270 27mH, 600mA
7 Diode (DB01) D3SBA60 4 A, 600 V
8 Capacitor (C03) EKMH451VSN121MQ35S 120 µF, 450 V
9 Fuse (F01) BET6.3A 6.3 A, 250 V
10 Varistor (R09, R10) SR561K14DO 560 V
11 Resistor (R01) RF-5TK1R8
No.
1.8 ,
P
5W
ar
1
ts name
2
T
Lou
ype
v
Specifications
er motor MP24Z3T
Output (Rated) 2 W, 16 poles, 4 phase,
DC 12 V
13
G5NB-1A-CA
Relay : (RY03)
Coil DC 12V, 16.7mA, Contact AC 250V, 3A
4-2. Outdoor Unit (RAS-24SA-ES2)
No. Parts name Type Specifications
Output (Rated) 2000W, 2poles, 1 phase, 220-240V 50Hz
1 Compressor PA271X3CS-4MU2 Winding resistance ( ) Red-Black White-Black
(at 20°C) 1.27 2.10
Output (Rated) 42W, 4poles, 1 phase, 220 240V, 50Hz
2 Fan motor (for outdoor) WLF-240-85A Winding resistance () Red-Black White-Black
(at 20° C) 70.5 120.1
3
Running capacitor
DS451355NPQB AC 450V, 3.0µ F
(for fan motor)
4
Running capacitor
B
32332I5606J063 A
C 450V, 60µ F
(for compressor)
5
Magnetic contactor
A35P 220-240V, 50Hz

Table of Contents

Related product manuals