– 7 –
• For performance when each indoor unit is combined with other unit, refer to the separate table.
• The specifications may be subject to change without notice for purpose of improvement.
<Cooling Only Models>
RAS-M10GKCVP-E, RAS-M13GKCVP-E, RAS-M16GKCVP-E / RAS-4M27GACV-E
Indoor
RAS-M10GKCVP-E, RAS-M13GKCVP-E, RAS-M16GKCVP-E
Unit model
Outdoor
RAS-4M27GACV-E
Cooling capacity (kW) 8.0
Cooling capacity range (kW) 1.4 – 9.2
Heating capacity (kW) —
Heating capacity range (kW) —
Power supply 220–240 V, 1 Ph, 50Hz / 220 V, 1 Ph, 60Hz
Unit model
RAS-M10GKCVP-E RAS-M13GKCVP-E RAS-M16GKCVP-E
Running current (A) 0.15 0.15 0.15
Power consumption (W) 30 30 30
Indoor
Power factor (%) 91/87/83 91/87/83 91/87/83
Unit model
RAS-4M27GACV-E
Running current (A) 11.60/11.09/10.63
Power consumption (W) 2500
Power factor (%) 98
Electric
characteristics
Outdoor
Starting current (A) 11.60/11.09/10.63
COP 3.20
Unit model
RAS-M10GKCVP-E RAS-M13GKCVP-E RAS-M16GKCVP-E
High (dB•A) 42 43 45
Medium (dB•A) 33 34 36
Indoor
Low (dB•A) 27 27 29
Unit model
RAS-4M27GACV-E
Operating
noise
Outdoor
Full indoor units operating (dB•A) 48
Unit model
RAS-M10GKCVP-E RAS-M13GKCVP-E RAS-M16GKCVP-E
Height (mm) 250 250 250
Width (mm) 790 790 790Dimension
Depth (mm) 215 215 215
Net weight (kg) 9 9 9
Fan motor output (W) 30 30 30
Indoor unit
Air flow rate (m³/h) 550 560 640
Unit model
RAS-4M27GACV-E
Height (mm) 795
Width (mm) 900Dimension
Depth (mm) 320
Net weight (kg) 63
Motor output (W) 2000
Type Twin rotary type with DC-inverter variable speed controlCompressor
Model DA220A2F-20L
Fan motor output (W) 60
Air flow rate (m³/h) High : 3000, Medium : 2800
Outdoor unit
Ty p e Flare connection
Unit model
RAS-M10GKCVP-E RAS-M13GKCVP-E RAS-M16GKCVP-E
Indoor unit
Liquid side/Gas side Ø6.35/ Ø9.52 Ø6.35/ Ø9.52 Ø6.35/ Ø12.7
Unit model
RAS-4M27GACV-E
A unit liquid side/Gas side Ø6.35/ Ø12.7
B unit liquid side/Gas side Ø6.35/ Ø9.52
C unit liquid side/Gas side Ø6.35/ Ø9.52
Outdoor unit
D unit liquid side/Gas side Ø6.35/ Ø9.52
Maximum length (per unit) (m) 25
Maximum length (total) (m) 70
Maximum chargeless length (m) 70
Maximum height difference (m) 15
Name of refrigerant R410A
Piping
connection
Weight (kg) 2.2
Power supply 3 Wires : includes earth
Wiring connection
Interconnection 4 Wires : includes earth
Indoor (°C) 21 to 32
Usable temperature range
Outdoor (°C) 10 to 43
Unit model
RAS-M10GKCVP-E RAS-M13GKCVP-E RAS-M16GKCVP-E
Installation plate 1 1 1
Wireless remote controller 1 1 1
Batteries 2 2 2
Remote controller holder 1 1 1
Zeolite-plus filter 1 1 1
Plasma pure filter 1 1 1
Remote controller holder mounting screw 2 (Ø3.1 × 16L) 2 (Ø3.1 × 16L) 2 (Ø3.1 × 16L)
Owner’s manual 1 1 1
Mounting screw 6 (Ø4 × 25L) 6 (Ø4 × 25L) 6 (Ø4 × 25L)
Indoor unit
Installation manual 1 1 1
Unit model
RAS-4M27GACV-E
Installation manual 1
Accessory
Outdoor unit
Specifications 1