EasyManua.ls Logo

Toshiba RAS-B10J2KVSG-E - Page 8

Toshiba RAS-B10J2KVSG-E
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Unit model Indoor
RAS-B16J2KVSG-E, RAS-B16N4KVSG-E
Outdoor
RAS-16J2AVSG-E
Cooling capacity (kW)
Cooling capacity range (kW)
Heating capacity (kW)
Heating capacity range (kW)
Power supply
1Ph/220-240V/50Hz
Electric Indoor Operation mode Cooling Heating
characteristic Running current (A) 0.31-0.29 0.31-0.29
Power consumption (W) 45 45
Power factor (%) 65 65
Outdoor Operation mode Cooling Heating
Running current (A) 6.14-5.61 7.24-6.61
Power consumption (W) 1305 1475
Power factor (%) 97 93
Starting current (A)
COP (Cooling / Heating) 3.41/3.62
Operating Indoor High (Cooling / Heating) (dB-A) 44/44
noise Medium (Cooling / Heating) (dB-A) 35/35
Low (Cooling / Heating) (dB-A) 25/26
Outdoor (Cooling / Heating) (dB-A) 48/50
Indoor unit Unit model
RAS-B16J2KVSG-E, RAS-B16N4KVSG-E
Dimension Height (mm) 293
Width (mm) 800
Depth (mm) 226
Net weight (kg) 10
Fan motor output (W) 30
Air flow rate (Cooling / Heating)
(m
3
/ min)
13/13
Outdoor unit Unit model
RAS-16J2AVSG-E
Dimension Height (mm) 550
Width (mm) 780
Depth (mm) 290
Net weight (kg) 33
Compressor Motor output (W) 890
Type
Model KSN108D22UFZ
Fan motor output (W)
Air flow rate (Cooling / Heating)
(m
3
/ min)
34/34
Piping Type Flare connection
connection Indoor unit Liquid side (mm)
6.35
Gas side (mm)
12.70
Outdoor unit Liquid side (mm)
6.35
Gas side (mm)
12.70
Maximum length (m) 20
Maximum charge-less length (m) 15
Maximum height difference (m) 12
Refrigerant Name of refrigerant R32
Weight (kg) 0.80
Wiring Power supply 3 Wires: Includes earth (Outdoor)
connection Interconnection 4 Wires: Includes earth
Usable temperature range Indoor (Cooling / Heating)
(
o
C)
21-32/ -28
Outdoor (Cooling / Heating)
-15,46/-15,24
1.10-6.50
1.20-5.30
5.50
4.60
6.45-5.90 7.55-6.90
Single rotary type with DC-inverter variable speed control
* The specification may be subject to change without notice for purpose of improvement.
Accessory Indoor unit
Installation plate
1
Wireless remote controller
1
Batteries 2
Remote controller holder
1
Toshiba IAQ filter
1
Mounting screw
6(4x25L)
Remote controller holder
Flat head wood screw
Installation manual 1
Owner's manual
1
2(3.1x16L)
(
o
C)
43
- 8 -

Table of Contents

Other manuals for Toshiba RAS-B10J2KVSG-E

Related product manuals