2-2. Operation Characteristic Curve
<Cooling> <Heating>
2-3. Capacity Variation ratio According to Temperature
<Cooling> <Heating>
- 9 -
0
2
4
6
8
10
12
0 10 20 30 40 50 60 70 80 90 10 0 110
Current (A)
Compressor Speed (RPS)
0
2
4
6
8
10
12
0 10 20 30 40 50 60 70 80 90 100 110
Current (A)
Compressor Speed (RPS)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C/WB 24
o
C
Indoor Air Flow : High
Pipe Length : 5m
Voltage : 230V/ 50Hz
Conditions
Indoor : DB 20
o
C/WB 15
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Indoor Air Flow : High
Pipe Length : 5m
Voltage : 230V / 50Hz
RAS-B16J2KVSG-E
RAS-B13J2KVSG-E
RAS-B10J2KVSG-E
RAS-B07J2KVSG-E
RAS-B16J2KVSG-E
RAS-B10J2KVSG-E
RAS-B07J2KVSG-E
50
55
60
65
70
75
80
85
90
95
100
105
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Cooling Capacity ratio (%)
Outside Temperature (
o
C)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C/WB 24
o
C
Indoor Air Flow : High
Pipe Length : 5m
Voltage : 230V / 50Hz
Capacity ratio : 100 %=
2.00kW(RAS-B07J2KVSG-E)
2.50kW(RAS-B10J2KVSG-E)
3.50kW(RAS-B13J2KVSG-E)
4.60kW(RAS-B16J2KVSG-E)
RAS-B16J2KVG-E
RAS-B13J2KVSG-E
Heating Capacity ratio (%)
120
100
80
60
40
20
0
-15 -10 -5 0
Outside Temperature ( ºC)
5 10
Capacity ratio : 100 %=
2.50kW(RAS-B07J2KVSG-E)
3.20kW(RAS-B10J2KVSG-E)
4.20kW(RAS-B13J2KVSG-E)
5.50kW(RAS-B16J2KVSG-E)
Conditions
Indoor : DB 20
o
C/WB 15
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Indoor Air Flow : High
Pipe Length : 5m
Voltage : 230V / 50Hz