8
Piping and Drain Hose Installation
* Since dewing results in a machine trouble, make sure to insulate both
connecting pipes. (Use polyethylene foam as insulating material.)
Piping and drain hose forming
1. Die-cutting back body slit
Cut out the slit on the left or right side of the back body for the left or right
connection and the slit on the bottom left or right side of the back body
for the bottom left or right connection with a pair of nippers.
Rear right
Rear left
Bottom left
Left
Bottom right
Right
Die-cutting
back body slit
Changing
drain hose
Piping preparation
2. Changing drain hose
For leftward connection, bottom-leftward connection and rearleftward
connection’s piping, it is necessary to change the drain hose and drain
cap.
1. Remove cover of remote controller by sliding down and take it out.
2. If batteries are exist, please take them out. The combination of using
wire controller and batteries may cause of batteries explosion.
3. Make hole for insert control wire by use screwdriver break the plastic for
cover hole as shown on gure 4.
4. Insert control wire from rear side of remote controller as shown on
gure 5.
5. Fix control wire which arrange as shown on gure 6 and 7 to terminal
by provided screws (tighten rmly but not over 0.25 N·m (0.03 kgf·m)).
6. Set control wire through gutter way at rear side of remote controller as
shown on gure 8.
7. Fix provided screw (Ø3.1×16L) on the wall to hang remote controller as
shown on gure 9.
8. Mark and arrange hole for x below screw (Ø3.1×25L) as shown on
gure 9.
9. Assembly battery cover which provided with accessory bag then use
provide screw (Ø3.1×25L) to x battery cover together with wall as
shown on gure ! (tighten rmly but not over 0.15 N·m (0.02 kgf·m)).
10. Reassembly cover of remote controller.
For remote controller
*Remark : 1. Recommend to use double insulation lead wire for connect
remote control and air conditioner.
2. For wire operation, 1 remote control can control only 1 indoor
unit.
3. In wire operation, remote controller will return to initial
condition (PRESET, TIMER and CLOCK will return to
initial condition) when user shutdown power supply of air
conditioner.
2
3
* Wire size 28-22AWG
or 0.08-0.32 mm
2
Outer diameter not over 4.7 mm,
control wire length 30 m. or less.
70 mm
5 mm
Terminal
Control wire
Notch for wire out
Control wire
Display
unit
1
Screw
Screw cap
Screw
Front panel
Control wire
Hole for hang
remote controller
Remote controller
Control wire
Screw (Ø3.1×16L)
for hang remote
controller
Wall
Screw (Ø3.1×25L)
for x battery cover
Remote controller
89
!
Battery cover
Screw
Tighten rmly but not over
0.15 N·m (0.02 kgf·m)
1.5V
1.5V
1.5V
1.5V
45
Control wire
6
7
Control wire
Terminal
Plastic for cover hole
* Wire size 28-22AWG
or 0.08-0.32 mm
2
Outer diameter not over 4.7 mm,
control wire length 30 m. or less.
30 mm
5 mm
20 mm