– 22 −
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1
Reactor
L = 10mH, 16A
2 Outdoor fan motor DC140V, 43W
3 Suction temp. sensor (TS sensor)
10k (25°C)
4 Discharge temp. sensor (TD sensor)
62k (20°C)
5 Outside air temp. sensor (TO sensor)
10k (25°C)
6 Heat exchanger temp. sensor (TE sensor)
10k (25°C)
7 Terminal block (5P) AC250V, 20A
9 Coil for PMV DC12V
10 Coil for 4-way valve AC220-240V
CAM-MD12TCTH-5
STF-01AJ646A1
Compressor 3-phases 4-poles
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA89X1C-23FZ2
DA130A1F-27F
Parts name Model name Rating
CH-57
ICF-140-43-4R
RAS-18SAV2-E
RAS-10SAV2-E, RAS-13SAV2-E
RAS-18SAV2-E
RAS-10SAV2-E, RAS-13SAV2-E
L = 19mH, 10A
CH-69
No.
Fan motor (for indoor)
2 Room temp. sensor (TA-sensor)
10k
Ω at 25°C
3
Heat exchanger temp. sensor (TC-sensor)
10kΩ at 25°C
5
Louver
motor
Output (Rated) 1W, 16 poles, DC12V
( - )
(
-
)
MP24Z3T
ICF-340-41-1 DC340, 41W
Parts name
1
Specif icationsType
6
Dumper motor
Output (Rated) 1W, 16 poles, DC12V
MP24Z3T
4
10kΩ at 25°C
(
-
)
Heat exchanger temp. sensor (TCJ-sensor)