EasyManua.ls Logo

Toshiba RAS-B10UFV-E - Page 27

Toshiba RAS-B10UFV-E
127 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
8-2. Outdoor Unit (Inverter Assembly)
220–240 V ~50Hz
MICRO-COMPUTER BLOCK DIAGRAM
Driver circuit
of P.M.V.
Indoor unit
send/receive
circuit
Relay
circuit
Noise
Filter
Converter
(AC DC)
Clock
frequency
4MHz
High Power
factor Correction
circuit
Input current
sensor
• PWM synthesis function
• Input current release control
• IGBT over-current detect control
• Outdoor fan control
• High power factor correction control
• Inverter output frequency control
• A/D converter function
• P.M.V. control
• Discharge temp. control
• 4-way valve control
• Signal communication to indoor unit
P.M.V. : Pulse Motor Valve
M.C.U. : Micro Control Unit
M.C.U
For INDOOR UNIT
4-way
valve
P.M.V.
Inverter
(DC AC)
Gate drive
circuit
Gate drive
circuit
Inverter
(DC AC)
Heat exchanger
temp.sensor (TE)
Suction temp.
sensor (TS)
Outdoor air
temp. sensor (TO)
Discharge
temp. sensor (TD)
Outdoor
Fan motor
220
230V ~60Hz
MCC5009 (P.C.B) OUTDOOR UNIT
Current
detect
Current
detect
Compressor

Table of Contents

Related product manuals