(Table 2) Indoor fan air flow rate <Heating>
Fan speed
level
Fan speed Air flow rate Fan speed Air flow rate Fan speed Air flow rate
(rpm) (m3/h) (rpm) (m3/h) (rpm) (m3/h)
WF UH 560 528 600 570 690 666
WE H 540 510 580 552 670 642
WD M+ 500 468 520 486 600 570
WC 440 408 480 444 570 540
WB M 380 342 390 354 520 486
WA 380 342 390 354 460 426
W9 L+ 380 342 390 354 460 426
W8 L 300 258 350 312 400 366
W7 L- 260 216 340 300 360 324
W6 260 216 270 228 340 300
W5 UL 260 216 270 228 340 300
W4 260 216 270 228 340 300
W3 260 216 270 228 340 300
W2 SUL 240 198 250 210 320 282
W1 240 198 240 198 240 198
RAS-B13UFV-E RAS-B18UFV-E
HEAT
RAS-B10UFV-E
35
Item
Operation flow and applicable data, etc.
Description
[In starting and in stability]
FAN AUTO
FAN Manual
In starting
Until 12 minutes passed after operation start
When 12 to 25 minutes passed after operation
start and room temp. is 3°C or lower than set temp.
Room temp. < Set temp.4°C
In stability
When 12 to 25 minutes passed after operation start
and room temp. is higher than (set temp. –3°C)
When 25 minutes or more passed after operation start
Room temp. = Set temp. –3.5°C