– 18 –
6-2. Outdoor Unit
RAS-10EAVP-E, RAS-13EAVP-E, RAS-16EAVP-E
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
RAS-B10EKVP-E, RAS-B13EKVP-E, RAS-B16EKVP-E
No.
1
2
3
4
Parts name
Fan motor (for indoor)
Room temp. sensor
(TA-sensor)
Heat exchanger temp. sensor
(TC-sensor)
Louver motor
Type
MF-280-30-5
( – )
( – )
MP24GA
Specifications
DC280–340V, 30W
10k at 25°C
10k at 25°C
Output (Rated) 1W, 16poles, 1phase DC12V
No.
1
2
3
4
5
6
7
8
9
10
Parts name
Reactor
Outdoor fan motor
Suction temp. sensor
(TS sensor)
Discharge temp. sensor
(TD sensor)
Outside air temp. sensor
(TO sensor)
Heat exchanger temp. sensor
(TE sensor)
Terminal block (6P)
Compressor
Coil for PMV
Coil for 4-way valve
Model name
CH-57
ICF-140-43-4
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA111A1F-20F1
CAM-MD12TF
VHV
Rating
L=10mH, 16A x 2
DC140V, 43W
10k (25°C)
62k (20°C)
10k (25°C)
10k (25°C)
20A, AC250V
3-phases 4-poles 750W
DC12V
AC220-240V