– 21 –
7-2. Operation Data
<Cooling>
<Heating>
NOTES :
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
(2) Connecting piping condition : 7.5 m
Temperature
condition (°C)
Indoor Outdoor
27/19 35/–
Heat exchanger
pipe temp.
T1 (°C) T2 (°C)
13 to 15 42 to 44
11 to 14 42 to 45
8 to 11 43 to 47
Model
name
RAS-
B10EKVP-E
B13EKVP-E
B16EKVP-E
Standard
pressure
P (MPa)
0.9 to 1.1
0.8 to 1.0
0.7 to 0.9
Indoor fan
mode
High
High
High
Outdoor fan
mode
High
High
High
Compressor
revolution
(rps)
37
59
82
Temperature
condition (°C)
Indoor Outdoor
20/– 7/6
Heat exchanger
pipe temp.
T1 (°C) T2 (°C)
37 to 39 0 to 3
42 to 45 0 to 2
48 to 49 0 to 2
Model
name
RAS-
B10EKVP-E
B13EKVP-E
B16EKVP-E
Standard
pressure
P (MPa)
2.2 to 2.4
2.5 to 2.7
2.8 to 3.0
Indoor fan
mode
High
High
High
Outdoor fan
mode
High
High
High
Compressor
revolution
(rps)
54
65
86