2. SPECIFICATIONS
2-1. Specifications
RAS-B10EKVP-E/RAS-10EAVP-E, RAS-B13EKVP-E/RAS-13EAVP-E, RAS-B16EKVP-E/RAS-16EAVP-E
The specifications may be subject to change without notice for purpose of improvement.
Indoor
RAS-B10EKVP-E RAS-B13EKVP-E RAS-B16EKVP-E
Unit model
Outdoor
RAS-10EAVP-E RAS-13EAVP-E RAS-16EAVP-E
Cooling capacity (kW) 2.5 3.5 4.5
Cooling capacity range (kW) 0.5–3.5 0.6–4.5 0.8-5.0
Heating capacity (kW) 3.2 4.2 5.5
Heating capacity range (kW) 0.6–5.8 0.6–6.6 0.8-7.8
Power supply 1Ph/50Hz/220–240 V, 1Ph/60Hz/220 V
Operation mode
Cooling Heating Cooling Heating Cooling Heating
Running current (A) 0.15 0.15 0.15 0.15 0.15 0.15
Power consumption (W) 30 30 30 30 30 30
Indoor
Power factor (%) 87 87 87 87 87 87
Operation mode
Cooling Heating Cooling Heating Cooling Heating
Running current (A) 2.48/2.37/2.26 3.25/3.10/2.96 4.25/4.06/3.89 4.52/4.31/4.13 6.45/6.17/5.90 7.07/6.76/6.47
Power consumption (W) 520 680 890 945 1350 1480
Power factor (%) 95 95 95 95 95 95
Electric
character-
istics
Outdoor
Starting current (A) 3.40/3.25/3.11 4.67/4.46/4.28 7.22/6.91/6.62
COP (Cooling/Heating) 4.55/4.51 3.80/4.31 3.26/3.64
High (Cooling/Heating) (dB•A) 42/43 43/44 45/45
Medium (Cooling/Heating) (dB•A) 33/34 34/35 36/36
Indoor
Low (Cooling/Heating) (dB•A) 27/27 27/27 29/29
Operating
noise
Outdoor (Cooling/Heating) (dB•A) 46/47 48/50 49/50
Unit model
RAS-B10EKVP-E
RAS-B13EKVP-E
RAS-B16EKVP-E
Height (mm) 250 250 250
Width (mm) 790 790 790
Dimension
Depth (mm) 215 215 215
Net weight (kg) 9 9 9
Fan motor output (W) 30 30 30
Indoor unit
Air flow rate (Cooling/Heating) (m³/h) 550/610 560/640 640/660
Unit model
RAS-10EAVP-E
RAS-13EAVP-E
RAS-16EAVP-E
Height (mm) 550 550 550
Width (mm) 780 780 780
Dimension
Depth (mm) 290 290 290
Net weight (kg) 35 37 37
Motor output (W) 750 750 750
Type Twin rotary type with DC-inverter variable speed control
Compressor
Model DA111A1F-20F1 DA111A1F-20F1 DA111A1F-20F1
Fan motor output (W) 43 43 43
Outdoor
unit
Air flow rate (Cooling/Heating) (m³/h) 2150/2150 2410/2410 2410/2410
Type Flare connection Flare connection Flare connection
Liquid side Ø6.35 Ø6.35 Ø6.35 Indoor unit
Gas side Ø9.52 Ø9.52 Ø12.7
Liquid side Ø6.35 Ø6.35 Ø6.35 Outdoor unit
Gas side Ø9.52 Ø9.52 Ø12.7
Maximum length (m) 25 25 25
Maximum chargeless length (m) 15 15 15
Piping
connection
Maximum height difference (m) 10 10 10
Name of refrigerant R410A R410A R410A Refrigerant
Weight (kg) 0.82 0.96 0.96
Power supply 3 Wires : includes earth (Outdoor) Wiring
connection
Interconnection 4 Wires : includes earth
Indoor (Cooling/Heating) (°C) 21–32/0–28 21–32/0–28 21–32/0–28 Usable temperature range
Outdoor (Cooling/Heating) (°C) 5–43/–15–24 5–43/–15–24 5–43/–15–24
Installation plate 1 1 1
Wireless remote controller 1 1 1
Batteries 2 2 2
Remote controller holder 1 1 1
Zeolite-plus filter 1 1 1
Mounting screw 6 (Ø4 x 25L) 6 (Ø4 x 25L) 6 (Ø4 x 25L)
Remote controller holder
mounting screw
2 (Ø3.1 x 16L) 2 (Ø3.1 x 16L) 2 (Ø3.1 x 16L)
Plasma Pure filter 1 1 1
Installation manual 1 1 1
Indoor unit
Owner’s manual 1 1 1
Drain nipple 1 1 1
Accessory
Outdoor unit
Water-proof rubber cap 2 2 2