32
Item
2. Indoor fan
motor control
Operation flow and applicable data, etc.
<In cooling operation>
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
Description
* Symbols
UH : Ultra High
H : High
M+ : Medium+
M : Medium
L+ : Low+
L: Low
L- : Low
UL : Ultra Low
SUL : Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
(Fig. 1)
(Fig. 2)
(Table 1) Indoor fan air flow rate
+2.5
Ta
[
˚C
]
+2.0
+1.5
+1.0
+0.5
Tsc
a
b
c
d
e
M+(WB)
*3
*4
*5
L(W6)
Air volume AUTO
L
L+
M
M+
H
W6
(L + M) / 2
W9
(M + H) / 2
WC
Indication
Fan speed
Fan speed setup
COOL ON
AUTO
MANUAL
*3 : Fan speed = (M + L) x 3/4 + L
*4 : Fan speed = (M + L) x 2/4 + L
*5 : Fan speed = (M + L) x 1/4 + L
(Linear approximation
from M+ and L)
FILE NO. SVM-15006
RAS-B10N3KV2-E1 RAS-B13N3KV2-E1
Cooling Heating Cooling Heating
Fan speed Air flow rate
(rpm) (m3/h)
Fan speed Air flow rate
(rpm) (m3/h)
Fan speed Air flow rate
(rpm) (m3/h)
Fan speed Air flow rate
(rpm) (m3/h)
WF UH 1120 515 1200 565 1300 627 1300 627
WE UH H 1120 515 1200 565 1300 627 1300 627
WD H M+ UH 1120 515 1100 502 1200 565 1190 558
WC M+ H 1040 465 1000 440 1090 496 1080 490
WB M M+ 1000 440 1000 440 1080 490 1080 490
WA M M 960 415 870 359 980 428 980 428
W9 L+ 900 378 870 359 980 428 980 428
W8 L+ L L+ 860 353 750 284 880 365 870 359
W7 L L- 780 303 700 253 770 297 770 297
W6 L- L 650 222 650 222 770 297 770 297
W5 UL UL L- 620 203 650 222 720 266 720 266
W4 UL 600 191 520 141 690 247 690 247
W3 SUL SUL/SL- 580 179 520 141 670 235 670 235
W2 SUL 540 154 520 141 520 141 520 141
W1 500 129 500 129 500 129 500 129
RAS-B16N3KV2-E1
Cooling Heating
Fan speed Air flow rate
(rpm) (m3/h)
Fan speed Air flow rate
(rpm) (m3/h)
WF UH 1510 758 1510 758
WE UH H 1480 730 1510 758
WD H M+ UH 1430 708 1480 730
WC M+ H 1280 615 1430 708
WB M M+ 1280 615 1280 615
WA M M 1150 534 1220 577
W9 L+ 1100 502 1150 534
W8 L+ L L+ 980 428 1000 440
W7 L L- 920 390 980 428
W6 L- L 900 378 920 390
W5 UL UL L- 840 340 900 378
W4 UL 840 340 840 340
W3 SUL SUL/SL- 770 297 770 297
W2 SUL 620 203 620 203
W1 520 141 520 141
Fan speed
level
Fan speed
level
Cool Heat Dry
Mode
Mode
Cool Heat Dry