– 57 –
FILE NO. SVM-15006
10-3-2. Cutting a hole and mounting installation
plate
<Cutting a hole>
When installing the refrigerant pipes from the rear.
1. After determining the pipe hole position on the
mounting plate (A), drill the pipe hole (∅65 mm) at
a slight downward slant to the outdoor side.
NOTE
• When drilling a wall that contains a metal lath, wire
lath or metal plate, be sure to use a pipe hole brim
ring sold separately.
<Mounting the installation plate>
Fig. 10-3-3
CAUTION
· Direct sunlight to the indoor unit’s wireless
receiver should be avoided.
· The microprocessor in the indoor unit should not
be too close to RF noise sources.
(For details, see the owner’s manual.)
<Remote control>
· A place where there are no obstacles such as a
curtain that may block the signal from the indoor
unit.
· Do not install the remote control in a place exposed
to direct sunlight or close to a heating source, such
as a stove.
· Keep the remote control at least 1 m apart from the
nearest TV set or stereo equipment. (This is
necessary to prevent image disturbances or noise
interference.)
· The location of the remote control should be
determined as shown below.
Fig. 10-3-1
45
°
45
°
75
°
(Top view)
Indoor unit
Reception
range
Reception
range
Remote
control
Indoor unit
Remote control
(Side view)
10-3. Indoor Unit
.
.
.
.
10-3-1. Installation place
.
A place which provides the spaces around the
indoor unit as shown in the diag
ram in part 8-2.
Mounting screw
Pipe hole
Pipe hole
Indoor unit
Thread
Weight
A place where there is no obstacle near the air inlet
and outlet.
170
62
85
82.5
Hook
Anchor bolt holes
2 m or more from floor
Hook
A place that allows easy installation of the piping to
the outdoor unit.
A place which allows the front panel to be opened.
Hook
The indoor unit shall be installed as top of the indoor
unit comes to at least 2 m height. Also, it must be
avoided to put anything on the top of the indoor unit.
Installation
plate
∅
65 mm
100 mm
Pipe
hole
Fig. 10-3-2
The center of the pipe
hole is above he arow
①
⑦