EasyManua.ls Logo

Toshiba RAS-M10GDCV-E - Page 54

Toshiba RAS-M10GDCV-E
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
54
No.
2
Part name
Electrical
parts
assembly
Procedure
1) Remove two fixing screws
(Ø4x10L) of the TC sensor cover
to remove the sensor cover.
2) Remove TC sensor from the heat
exchanger.
3) Disconnect the connector inserted
in the connector at the rear side of
the electric parts box.
4) Remove cover of the terminal
block.
(Ø4x10L : Grade 3 with washer)
5) Remove two fixing screws
(Ø4x10L) of the electric parts box
to pull out the electric parts box.
6) Remove two fixing screws
(Ø4x10L) of the electric parts box
cover to take out the electric parts
box cover.
Remaks
1
5
6
4
2
3

Other manuals for Toshiba RAS-M10GDCV-E

Related product manuals