– 10 –
Cooling
27°C
19°C
35°C
24°C
Heating
20°C
7°C
6°C
JIS C9612-1994Condition
(DB)
(WB)
(DB)
(WB)
Temperature
Indoor unit inlet air temperature
Outdoor unit inlet air temperature
Notes : *2
RAS-13SKH-E / RAS-3M31SAH-E-1
No additional refrigerant required.
This air conditioner accepts a connection piping length of up to 15m and a head of up to 6m.
There is no need to add the refrigerant as long as the total length of the connection piping is up to 15m.
RAS-10SKH-E-1 / RAS-M18SAH-E,
RAS-10SKH-E-1 / RAS-3M31SAH-E-1,
RAS-10SKH-E-1 / RAS-4M36SAH-E
This air conditioner accepts a connection piping length of up to 15m and a head of up to 5m.
There is no need to add the refrigerant as long as the total length of the connection piping is up to 10m.
There is need to add the refrigerant 20g/m as long as the each length of the connection piping is up to 11m to
15m.
Note : *1
Capacity is based on the following temperature conditions.