34 RemotEye 4 User Manual – 90988-007
Figure 4-3 Tera Term Opening Screen
4. Click on each drop-down box as necessary to
adjust the serial port settings.
5. Set the COM port parameters for:
Port: (COM port for SPEAr)
Baud rate: 9600
Data: 8 Bit
Parity: none
Stop: 1 bit
Flow control: none
Transmit Delay: 0
6. Click on the “OK” button.
7. Set the RemotEye 4 IP Address for the target
network. See Section 4.2.3 Set the IP
Address.
4.2.4 Set the IP Address
1. Install the Driver
2. Connect the USB to mini-USB adapter cable provided in the RemotEye 4 package.
3. Load and start a hyperterminal (Tera Term)
4. Look for the SPEAr COM Port number.
5. Click OK
6. Set the COM port for SPEAr to the following settings:
Baud 9600 baud
Data 8 bit
Parity None
Stop bit 1 bit
Flow Control None
7. Login. (The default Log in values are: User: TOSHIBA, Password: ADMIN)
8. The RemotEye 4 Configuration Utility main menu will be displayed. See Figure 4-5.