EasyManua.ls Logo

Toshiba RSM 100 - Displaying Harmonics

Toshiba RSM 100
173 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
124
6 F 2 S 0 7 1 5
Displaying Harmonics
This part describes how to display the harmonics for 4 cycles before and after the active cursor
position.
Note for Operation
You can select the primary values or the secondary values for the
fundamental wave of harmonics.
(2.1 Setting Parameters for Measurement and Analysis Selecting Options)
Operating Procedure
Display the active cursor at the measurement point.
On the [Measurement] menu, click [Harmonics].
The harmonics of the channels are displayed.
The harmonics for 4 cycles before and after the cursor position are calculated.
You can display the harmonics up to 11th by clickingNextbutton.
You can update the values by moving the cursor.
[--------] is displayed in the channel where the value can not be measured.
2-12

Table of Contents

Related product manuals