⎯ 89 ⎯
6 F 2 S 0 7 1 5
③ Click【Edit】button.
・ [Edit Binary Element] dialog box is displayed.
④ Type the name of measurement location in [Equip. Name] text box.
・ You can enter up to 32 characters for a name of measurement location.
⑤ Type the name of measurement element in [Elem. Name] text box.
・ You can enter up to 12 characters for a name of measurement element.
⑥ Click the down arrow button that appears just to the right of [Color] drop-down list box
and click the color in which you want display the waveform.
⑦ Click【OK】button.
・ The setting details are reflected in the display.
⑧ To set the parameters for other channel, repeat the steps ②~⑦.
・ When you want to set parameters for a channel with the settings that are almost same as a channel you
have already set, display [Edit Binary Element] dialog box of the latter channel. Then, click the down
arrow button that appears just to the right of [Ch] drop-down list box and click the channel you want to set.
The parameter settings of the new channel are the same as the previous channel. Modify only the
parameter settings that you need to modify.
⑨ To print the setting details of the element table, click【Print】button.
⑩ Click【OK】button.
・ The parameters for the binary elements are set.
1-13