EasyManua.ls Logo

Toshiba Satellite 110 Series - 3.19 Log Utilities

Toshiba Satellite 110 Series
192 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-42 110 Series
3.19 Log Utilities
3.19.1 Function Description
This function logs error information generated while a test is in progress and stores the
results in RAM. This function can store data on a floppy disk or output the data to a printer.
If the power switch is turned off, the error information will be lost. The error information
displays in the following order:
1. Error count (CNT)
2. Test name (TS-NAME)
3. Subtest number (TS-NAME)
4. Pass count (PASS)
5. Error status (STS)
6. FDD/HDD or memory address (ADDR)
7. Write data (WD)
8. Read data (RD)
9. HDC status (HSTS)
10. Error status name ( ERROR STATUS NAME)
3.19.2 Operations
1. Selecting 5 and pressing Enter in the Diagnostics Menu logs error information
into RAM or onto a floppy disk. The error information displays in the following
format:
XXXXX ERRORS
CNT TS-NAME PASS STS ADDR WD RD HSTS [STATUS NAME]
001 FDD 02 0000 103 00001 00 00 FDD - WRITE PROTECTED
001 FDD 01 0000 180 00001 00 00 FDD - TIME OUT ERROR
Address
Error status
Pass count HDC status
Subtest number Read data
Test name Write data
Error count Error status name
[[1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write]]

Table of Contents

Other manuals for Toshiba Satellite 110 Series

Related product manuals