REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
-26-
TABLE RM-Q
TYPE 1 PROGRAM PROCEDURE EXAMPLE
ACTIONSTEP DISPLAY/PRINTOUT
1 >MODE PROG
P
Enter Program Mode
At the >MODE prompt, enter P R O G CR.
2 P 10
P10
Enter Program Number
Refer to the record sheet and enter the desired program number.
Example: Program 10-1, enter 1 0, press CR.
3 P10 1Enter Program Code or Digit(s) Per Record Sheet
1 or other digit required.
4 P10 1 01 NEnter Button/LED Number
Enter the desired button/LED number.
Example: Button/LED 01, enter 0 1.
5 P10 1 01 N YTo Change Button/LED Status
Refer to the System Record Sheet and change the button/LED
status, if required (Y or N).
Example: Enter Y.
6
(PROGRAMS: 10-1, 10-2, 10-3, 15, 16, 42-0, 77-1, 77-2)
NOTE: Most programs do not require a second digit.
P10 1 01 Y-7
To Advance to Next Button/LED
Press SPACE. Repeat step 5 if necessary.
P10 1 01 Y
02 N
8 To Exit Program/Store Data
A)
B)
C)
P10
P10 ##
P
To store data, press CR.
To exit this program, press # #, then press CR.
Continue returning to step 2 until all Type 1 programs
are completed.
To Review Button/LED Status Change
Enter CR.
Re-enter Steps 3 and 4.
NOTE: This step is optional and not required to save data.
(see note)
9
10
To Exit the Program Mode
Press # # CR.
> MODE
To Enter Another Mode
Press
D U M P CR (data dump)
T E S T CR (test)
M E S G CR (LCD messages)
R E P T CR (speed dial)
D
T
R
(no prompt)
Button LED Number
Program Code
Program Number
NOTE:
Y = button/LED "ON", N = button/LED "OFF"
Button LED "ON"