REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
-27-
TABLE RM-R
TYPE 2 PROGRAM PROCEDURE EXAMPLE
ACTIONSTEP DISPLAY/PRINTOUT
1 >MODE PROG
P
Enter Program Mode
At the >MODE prompt, enter P R O G CR.
2 P 30Enter Program Number
Refer to the record sheet and enter the desired program number.
Example: Program 30, enter 3 0, press CR.
3 P30
P30 04
Enter Port Number
Refer to the System Record Sheet and enter the desired
port number(s). Example: 0 4.
4 P30 04#Press # button.
5 P30 04# 01 NEnter the Desired Button/LED Number
Example: Button/LED 01, enter: 0 1.
7
(PROGRAMS: 20, 30, 31, 35, 40, 41, 43, 79, 81 ~ 89)
8
To Advance to Next Button/LED
Press SPACE (repeat Step 6 if necessary).
9 To Exit Program/Store Data
A)
B)
C)
P10
P10 ##
P
To store data, press CR.
To exit this program, press # #, then press CR.
Continue returning to Step 2 until all Type 2 programs
are completed.
6 P30 04# 01 N YTo Change Button/LED Status
Refer to the System Record Sheet and change the button/LED
status, if required (Y or N).
Example: Enter Y.
10
11
(Note)
P30 04# 01 Y-
Button LED Number
Port Number
Program Number
To Review Button/LED Status Change
Press CR.
Re-enter Steps 3, 4, and 5.
>MODETo Exit the Program Mode
Press # # CR.
To Enter Another Mode,
D U M P CR (data dump)
T E S T CR (test)
M E S G CR (LCD messages)
R E P T CR (speed dial)
D
T
R
(no prompt)
NOTE:
Y = button/LED
(
s
)
"ON", N = button/LED
(
s
)
"OFF"; U = button/LED
(
s
)
"ON" some ports and "OFF" other ports.
or Port Range
*
Press
LED "ON"

Table of Contents