Loading...
Program 37 Ring Transfer (Camp-on) Recall Time
System & Station
Strata DK40 Programming Manual Spring 1999
3-81
Program 37
Ring Transfer (Camp-on) Recall Time
Program Type:
Station
Initialised Default:
Assigns Ring Transfer Recall Time of 32 seconds to all ports
Program 37 Overview
If a busy or ringing station does not answer a call sent to it via ring (blind) call transfer (lines
or [DNs]), the station originating the ring (blind) transfer is recalled after an amount of time
determined with this program. This time (011~999 seconds) is set independently for each
originating station port. Initialised data sets all stations for a 032-second recall time. Ring
Transfer must first be enabled for the system with Program 10-1, LED 07 ON.
(QWHU 3URJ 0RGH 0 6SNU 6:+ROG 0 6SNU & +ROG 0 6SNU & & +ROG 0 6SNU & & +ROG
Processor Port Range
DK40 000~027
Port Hold Time Port Hold Time
000 014
001 015
002 016
003 017
004 018
005 019
006 020
007 021
008 022
009 023
010 024
011 025
012 026
013 027
SELECT = Station Logical Port Number
Enter the port number that needs a Ring Transfer Recall Time assigned.
To add a port range, enter XXX
*
XXX (low port
*
high port).
HOLD TIME = Port Number
Enter the Ring Transfer Recall Time (three digits, in seconds)
Enter 000 for no Hold Recall. Enter 011~160 for 11 to 160
seconds.