EasyManua.ls Logo

Toshiba T1200 - Procedure 4: Output Voltage Check

Toshiba T1200
213 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROCBDORB
4
Output
Voltage
Check
1.
Turn
the
POWER
switch
off.
2.
Remove
the
power
supply
PCB.
(Refer
to
part
4.8)
3.
Plug
the
ac
adapter
into
an
electrical
outlet
and
the
DC
IN
l2V
jack.
4.
Turn
the
POWER
switch
on.
5.
Use
a
multimeter
to
confirm
that
the
output
voltages
for
the
three
power
supply
PCB
connectors
conform
to
the
values
given
in
the
following
table.
6.
If
the
voltages
conform
to
the
values
given
in
the
table,
the
power
supply
PCB
is
normal.
System
PCB
is
probably
defective,
go
to
system
PCB
isolation
procedures
in
part
2.4.
7.
If
the
voltages
do
not
conform
to
those
given
in
the
table,
go
to
PROCEDURE
6.
TABLE
2-1
Power
Supply
PCB
Output
Voltages
CONNECTOR
PIN
NUMBER VOLTAGE (Vdc)
+
lead
-lead
Normal
Min
Max
PJ
2
1
2
+ 5
+ 4.75
+ 5.25
PJ
4
6
3, 7, 10
+ 5
+ 4.75 + 5.25
8
3, 7, 10
+ 12
+ 11.4 + 12.6
9
3, 7,
10
-9
- 10.35
-7.65
12
3, 7, 10 - 22
- 23.1 -
20.9
PJ
5
1 GND
+ 5
+ 4.5
+ 5.5
2
GND
+ 5
+ 4.75
+ 5.25
3
GND
+ 12
+ 11.4 + 12.6
2-8