EasyManua.ls Logo

Toshiba T1900 Series - Page 43

Toshiba T1900 Series
183 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Procedure
5 Replacement
Check
The FL, FL inverter board, LCD module, and upper system board are connected
to
the display
circuits. Any
of
these components may be damaged. Refer to Chapter 4 for instructions on
how
to
disassemble the computer and then perform the following checks:
o
If
the FL does not light, perform Check
1.
o
If
characters are not displayed clearly, perform Check 3.
o
Ifsome
screen functions do not operate properly, perform Check 3.
o
If
the FL remains lit when the display is closed, perform Check 4.
Check 1 Replace the FL with a new one
and
test
the
display again.
If
the problem still
exists, perform Check 2.
Check 2 Replace the FL inverter board with a new one and test the display again.
If
the
problem still exists, perform Check 3.
Check 3 Replace the LCD module with a new one and test the display again.
If
the
problem still exists, perform Check
4.
Check 4 Replace the display switch with a new one and test the display
again.
If
the
problem still exists, perform Check
5.
Check 5 Replace the display cable with a new one and test the display again.
If
the
problem still exists, perform Check 6.
Check 6 The upper system board may
be
damaged. Replace the system board with a new
one and test the display
again.
2-26

Related product manuals