Procedure
5 Replacement
Check
The FL, FL inverter board, LCD module, and upper system board are connected
to
the display
circuits. Any
of
these components may be damaged. Refer to Chapter 4 for instructions on
how
to
disassemble the computer and then perform the following checks:
o
If
the FL does not light, perform Check
1.
o
If
characters are not displayed clearly, perform Check 3.
o
Ifsome
screen functions do not operate properly, perform Check 3.
o
If
the FL remains lit when the display is closed, perform Check 4.
Check 1 Replace the FL with a new one
and
test
the
display again.
If
the problem still
exists, perform Check 2.
Check 2 Replace the FL inverter board with a new one and test the display again.
If
the
problem still exists, perform Check 3.
Check 3 Replace the LCD module with a new one and test the display again.
If
the
problem still exists, perform Check
4.
Check 4 Replace the display switch with a new one and test the display
again.
If
the
problem still exists, perform Check
5.
Check 5 Replace the display cable with a new one and test the display again.
If
the
problem still exists, perform Check 6.
Check 6 The upper system board may
be
damaged. Replace the system board with a new
one and test the display
again.
2-26