Central remote controller Owner’s Manual
23
-EN
You can change the set temperature, operation mode, fan speed, and louver.
Depending on the range of the area to be set, display and operate the “Control” screen of All, Zone, or Unit.
Changing air conditioner Settings (Set Temperature, Operation Mode, Fan
Speed, and Louver)
1 Display the “Control” screen of All, Zone, or Unit (P.15)
2 Use [<] and [>] to select the item to change.
For details of the setting of each item, see the table below.
3 Make changes using [] and [], and then press [ ] (Confirm).
The changes to the settings are not reflected on the air conditioner
unless you press [ ] (Confirm).
123 4
No. Item Description
1
Set temperature You can change the set temperature using [] and [].
NOTE
The set temperature cannot be changed when the operation mode is Fan.
The temperature range that can be set differs depending on the operation mode.
If a temperature outside the set temperature range of the relevant operation mode is set, the
temperature is changed to the upper- or lower-limit temperature of the range.
2
Operation mode You can change the operation mode using [] and [].
NOTE
The operation modes that cannot be set are not displayed.
3
Fan speed You can change the fan speed using [] and [].
NOTE
The fan speeds that cannot be set are not displayed.
A blank is displayed if the fan speed is fixed.
4
Louver You can change the louver to the following, using [] and [].
NOTE
The louver position may differ for the header and follower units.
The setting range differs depending on the operation mode.
AUTO HEAT COOL FAN DRY
Swing
Swing stopped
F1 F2 F3 F4 F5
Operation Mode Setting range
Auto (Cool), Cool, Dry Swing Swing stopped F1 F2 F3 Swing (back to
the beginning)
Auto (Heat), Heat, Fan Swing Swing stopped F1 F2 F3 F4 F5
Swing (back to the beginning)

Table of Contents

Other manuals for Toshiba TCB-SC640U-E

Related product manuals