DUST-PROOF/WATER-PROOF TYPE INDUSTRIAL ROBOT SPECIFICATIONS MANUAL
STE 85338
– 24 –
5.3.3 Arm 1 Cover
The arm 1 cover is secured to the hexagonal supports attached to the arm 1 duct plate
by Phillips truss head screws (M4x8).
Liquid gasket is applied to the mounting surface of the packing. Therefore, when
removing the packing, remove the cover while using a scraper or other tool to gradually
peel off the liquid gasket.
When mounting the cover, fit the cover into the groove along the duct plate side.
Be careful that the packing does not come off.
Apply liquid gasket to the bearing faces of the Phillips truss head screws (M4x8) for
mounting the cover, and after mounting the cover, use liquid gasket to fill a gap
between the duct plate and cover.
Enlarged view of A
Fig. 5.3 Arm 1 cover
Enlarged
view of A
Arm 1 cover
Phillips truss
head screw
* The internal cables are
omitted from the
illustration.
Packing
Insert in this groove
Hexagonal
support
Duct plate