TRANSPORTATION AND INSTALLATION MANUAL
135
b-2) Output signal connector HAND (TSL3100E Type-P)
Output circuit and example of connections
The SYSPUTCOM signal is the same as that
of the pins 10 and 23 connected to the
OUTPUT connector on the controller front
face.
By using the 24 VDC power of the controller, a relay, solenoid valve, etc., can be driven.
To use external power supply, connect GND of the external power supply with the 24
VDC GND (P24G) of the robot controller (GND common connection). However, do
NOT connect the external power supply +24V with the 24 VDC (P24V) of the robot
controller. Otherwise, the power supply may be damaged.
Output specifications: Rated voltage: 24 VDC
Rated current: 100 mA
• When a relay or solenoid valve, etc., is connected, it is necessary to use a surge killer
or diode to absorb the surge voltage.
• The right figure shows the DC relay circuit when the external power is used.
●
●
お 客様側
【P24V(+)コモン 接続】
●
P24V
P24G
SYSOUTCOM
【 Source type(プ ラスコモン)】
D_OUT*_
●
●
[P24G( + )common connection]