EasyManua.ls Logo

Toshiba VF-PS1 - Page 244

Toshiba VF-PS1
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
K-2
E6581386
11
1. Basic parameter [2/4] Sensorless vector/vector with sensor (:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector
control
PM
control
V/f Reference
 0015 V/f control mode selection
0:Constant torque characteristics
1:Voltage decrease curve
2:Automatic torque boost
3:Sensorless vector control 1 (speed)
4:-
5:V/f 5-point setting
6:PM control
7:PG feedback control
8:-
9:Energy-saving
10:Advanced energy-saving
1/1 0 Disabled
-/-
-/-
/-
/-
-
-/-
-/-
-/
-
/-
/-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5. 6
 0016 Manual torque boost 1 0.0~30.0% 0.1/0.1 *1 Enabled - ●● 5. 7
 0014 Base frequency 1 25.0~500.0Hz 0.1/0.01 *3 Disabled /●●● 5. 8
 0409 Base frequency voltage 1
200V class:50~330V
400V class:50~660V
1/0.1 *1 Disabled /●●● 5. 8
 0011 Maximum frequency 30.0~500.0Hz 0.1/0.01 80.0 Disabled /●● 5. 9
 0012 Upper limit frequency 0.0~ Hz 0.1/0.01 *3 Enabled /●●●5. 10
 0013 Lower limit frequency 0.0~ Hz 0.1/0.01 0.0 Enabled /●●5. 10
 0009 Acceleration time 1 0.1~6000 sec. 0.1/0.1 *2 *1 Enabled /●●● 5. 2
 0010 Deceleration time 1 0.1~6000 sec. 0.1/0.1 *2 *1 Enabled /●●● 5. 2
 0213 RR/S4 input point 2 frequency 0.0~ Hz 0.1/0.01 *3 Enabled /●● 5. 11
 0204 VI/II input point 2 frequency 0.0~ Hz 0.1/0.01 *3 Enabled /●● 5. 11
 0018 Preset speed operation frequency 1 ~ Hz 0.1/0.01 0.0 Enabled /●●●5. 12
 0019 Preset speed operation frequency 2 ~ Hz 0.1/0.01 0.0 Enabled /●●●5. 12
 0020 Preset speed operation frequency 3 ~ Hz 0.1/0.01 0.0 Enabled /●●●5. 12
 0021 Preset speed operation frequency 4 ~ Hz 0.1/0.01 0.0 Enabled /●●●5. 12
 0022 Preset speed operation frequency 5 ~ Hz 0.1/0.01 0.0 Enabled /●●●5. 12
 0023 Preset speed operation frequency 6 ~ Hz 0.1/0.01 0.0 Enabled /●●●5. 12
 0024 Preset speed operation frequency 7 ~ Hz 0.1/0.01 0.0 Enabled /●●●5. 12
 0008
Forward run/reverse run selection
(operation panel operation)
0:Forward run
1:Reverse run
2:Forward run (Forward/reverse switchable on operation
panel)
3:Reverse run (Forward/reverse switchable on operation
panel)
1/1 0 Enabled /●●5. 13
*1: Default values vary depending on the capacity. See the table of K-41.
*2: Changing the parameter  enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).
*3: Inverter with a model number ending with -WN: 60.0 -WP: 50.0

Table of Contents