Advanced Setup
Page 13
Press
Press
Press
Press
Press
Continued
Select the reversing
valve polarity for
Heat Pump, O or B.
(Step 5 only appears if
heat pump is on in step 4)
Select Electric Heat On
or Off. (Step 6 only
appears if heat pump is
off in step 4)
Adjust the minimum
difference between
cooling & heating
setpoints.
Select the cycles per
hour limit.
d=cycles per hour
limit defeated.
d1=d + defeat 5 min.
Compressor lockout.
Adjust the deadband
from 1 - 6 degrees.
(0 - 6 )
(d, d1, 2 - 6)
B
On
Off
O
81f
MODE
MODE
MODE
MODE
MODE
0
5
Setup
Eh
6
OFF
Setup
2
7
Setup
88
2
8
COOL
HEAT
Setup
6
9
Cy
Setup