ADVANCED SETTINGS – SETTING THE DIFFERENTIAL
>
THE P286-1600 ALLOWS YOU TO CONTROL UP TO 2 STAGES OF
HEATING AND 1 STAGE OF COOLING, DEPENDENT ON THE TYPE OF
SYSTEM YOU HAVE CONFIGURED.
1
1
ST
STAGE DIFFERENTIAL:
Set temperature difference between temperature set point
and actual temperature reading before 1st stage heating or cooling is initiated.
2
2
ND
STAGE DIFFERENTIAL:
Set temperature difference between 1st stage initiation
and 2nd stage heating or cooling initiation.
3
OBW ENERGIZED:
Reverses the Heat Pump OBW Valve contact to HEAT or COOL
(manufacturer dependent).
33
ADVANCED SETTINGS – CONFIGURING YOUR EQUIPMENT
>
IMPORTANT: BY INADVERTENTLY MODIFYING COMPRESSOR AND
FURNACE SETTINGS, YOU MAY SERIOUSLY DEGRADE SYSTEM
PERFORMANCE.
>
CHOOSE SYSTEM HEATING AND/OR COOLING EQUIPMENT –
REMEMBER ALL YOU NEED TO DO IS TOUCH THE BUTTON WITH
YOUR FINGER.
1 Choose Heat Pump, 2 Stage Heat Pump, Air Conditioning, No Compressor –
please review the wiring table and diagram for wiring instructions.
2 Choose Furnace Off (No Furnace), Electric Furnace, Emergency Electrical Furnace
(additional electric furnace which will come on in emergency mode in conjunction
with electric furnace), Gas Furnace, Oil Furnace, and 2 Stage Gas Furnace; please
review the wiring table and diagram for wiring instructions.
3
CYCLE RATE:
Set the minimum difference between Auto Mode, Heat and Cool
temperature set points.
4
AUTO CHANGE:
Set Maximum compressor cycles per hour.
32