TEMPERATURE CALIBRATION TABLE
• Firstly, determine with a calibrated thermometer the temperature difference –
then use the following table to adjust your thermostat.
Thermostat Fahrenheit Celsius
Calibration Number Change Change
+3.0 +6F +3.0C
+2.5 +5F +2.5C
+2.0 +4F +2.0C
+1.5 +3F +1.5C
+1.0 +2F +1.0C
+0.5 +1F + .5C
Factory Setting 00 No Correction Required
-0.5 -1F -.5C
-1.0 -2F -1C
-1.5 -3F -1.5C
-2.0 -4 F -2.0C
-2.5 -5F -2.5C
-3.0 -6F -3.0C
ADVANCED SETTINGS – CALIBRATION
37
>
CALIBRATION OF TEMPERATURE
Your TotalTouch™ Thermostat is rated for an accuracy of +/-1 degree with
temperature
• If you have determined due to drafts, sunlight or other environmental factors that
your thermostat needs calibration, follow this easy guide. Common causes of off-
set are lack of air circulation in the vicinity of your TotalTouch™ unit or skylights.
ADVANCED SETTINGS – CALIBRATION
36