EasyManua.ls Logo

Town & Country Fireplaces TC36 User Manual

Default Icon
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SERIAL #
Visit www. townandcountry replaces.net for the most up-to-date version of this manual
TC36 & TC36 ARCH
INSTALLATION
AND OPERATING
INSTRUCTIONS
101215-52 TC36_D & TC36_DAR 5056.427D
MODEL: TC36 & TC36AR
SERIES D
MODULAR DIRECT VENT
FIREPLACE
WARNING: If the information in these
instructions is not followed exactly, a  re or
explosion may result causing property damage,
personal injury or death.
FOR YOUR SAFETY
Installation and service must be performed
by a quali ed installer, service agency or the
gas supplier.
WHAT TO DO IF YOU SMELL GAS
• Donottrytolightanyappliance.
• Donottouchanyelectricalswitch.
•Donotuseanyphoneinyourbuilding.
• Immediatelycallyourgassupplierfrom
a neighbours phone. Follow the gas
suppliers instructions.
• Ifyoucannotreachyourgassuppliercall
the  re department.
Do not store or use gasoline or other  ammable
vapors and liquids in the vicinity of this or any
other appliance.
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certi ed kit is used.
This appliance is suitable for installation in a
bedroom or bed sitting room.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Other manuals for Town & Country Fireplaces TC36

Question and Answer IconNeed help?

Do you have a question about the Town & Country Fireplaces TC36 and is the answer not in the manual?

Town & Country Fireplaces TC36 Specifications

General IconGeneral
BrandTown & Country Fireplaces
ModelTC36
CategoryIndoor Fireplace
LanguageEnglish

Summary

Caution and Safety Information

General Safety Precautions

Essential safety guidelines for operating the fireplace, including warnings about heat and proper use.

Massachusetts Installation Requirements

Fireplace Dimensions and Diagrams

Combustible Material Clearances

Mantel Clearance Specifications

Detailed clearance requirements for installing mantels above the fireplace.

Installation Requirements and Procedures

Mobile Home Installation

Guidelines for installing the fireplace in manufactured or mobile homes.

Door Frame Removal and Reassembly

Step-by-step instructions for removing and reinstalling the fireplace door frame.

Top Standoffs Installation

Locating The Fireplace

Framing and Finishing Guidelines

Non-Combustible Zone and Framing Kit

Critical areas to keep clear of combustibles and details on the steel stud framing kit.

TC 36D Minimum Combustible Framing Dimensions

TC 36D Arch Minimum Combustible Framing Dimensions

Non-Combustible Board Detail

Recessed Installation Detail

TC36 Steel Stud Framing Kits

Regular Stud Framing Kit Parts

Lists parts for the standard steel stud framing kit.

Arched Stud Framing Kit Parts

Lists parts for the arched steel stud framing kit.

Steel Stud Frame Assembly Steps

Adjustable Lintel Installation

Change the Lintel Edge

Steps to reorient the lintel for different finishing preferences.

Hearth Extension Requirements

Hearth Extension Thickness Warning

Warning about hearth extension thickness affecting door operation.

Electrical Connections and Installation

Wall Switch and Remote Control Setup

Linking Remote to Wall Switch

Procedure for establishing communication between the remote and wall switch.

Vent Mode Selection

Home Automation Integration

Gas Supply and Pressure Check

Venting Installation Overview

Wall Termination Venting

Instructions and charts for installing wall termination vent systems, including opening size and pipe routing.

Wall Vent Thimble and Components

Vent Pipe and Terminal Installation

Wall Vent Terminal

Procedures for installing the wall vent terminal.

Wall Termination Venting Chart

Roof Termination Venting Chart

Roof and Ceiling Venting Details

Ceiling Opening and Firestop

Instructions for ceiling openings, firestops, and vent pipes.

Roof Support Bracket Installation

Instructions for attaching the roof support bracket to the vent pipe.

Roof Vent Terminal Installation

Vent Terminal Clearances

Minimum Clearances to Adjacent Structures

Diagram and table illustrating required minimum clearances for vent terminals relative to buildings and other structures.

Detailed Vent Terminal Clearances

Detailed table of minimum clearances for various vent terminal locations and conditions.

Vent Pipe Sealing and Shielding

Insulated Collar Shield Installation

Steps for installing the insulated collar shield around the vent pipe.

Vent Restrictor Adjustment

Firestop Thimble and Termination Kits

Wall Termination Kit Details

Details and illustration of the wall termination kit components.

Roof Termination Kit Details

Details and illustration of the roof termination kit components.

Vent Pipe Component Dimensions

Vent Offset Configuration Chart

Firebox Panel Installation Procedure

Finishing Touch Trim Kit Installation

Fireplace Lighting Instructions

Initial Fireplace Operation

First Fire Observations

Notes on initial startup odors and normal operational noises.

Remote Control Basics

Introduction to operating the fireplace using the Proflame 2 remote control handset.

Proflame 2 System Description

Transmitter (Remote Control) Features

Details the features and power of the Proflame 2 remote transmitter.

IFC Module Functionality

Explains the function of the Integrated Fireplace Control module.

Fireplace Initialization Procedure

Step-by-step guide for first-time setup, battery installation, and synchronizing the remote.

Using the Remote Control Transmitter

Manual Bypass of the Remote Fireplace

How to operate the fireplace manually using the wall switch.

Flame and Thermostat Control

Smart Thermostat Operation

How the smart thermostat feature adjusts flame height based on room temperature.

Enabling Thermostat for Canadian Users

Specific procedure for enabling thermostat functionality for Canadian users.

Advanced Remote Control Features

Remote Dimmer Control for Lights

How to adjust light intensity using the remote control.

Pilot Mode Selection (CPI/IPI)

How to select between continuous or intermittent pilot ignition modes.

Appliance Maintenance and Inspection

Glass Panel Care and Replacement

Guidelines for cleaning, inspecting, and replacing the fireplace glass panel.

Annual Inspection Checklist

Key items to check during the annual maintenance inspection for safety and performance.

TC36 D Replacement Parts Catalog

TC36.DAR Replacement Parts Catalog

Valve Control System Replacement Parts

Electrical Wiring Diagram

Appliance Rating Label Information

Related product manuals